We’re proud to announce that R.L. Deppmann has expanded its territory to include West Michigan and is now the official manufacturer’s representative for Danfoss across …
Domestic Water Recirculation Systems Part 5: Settings
High Rise Considerations The last article, Part 4, showed an example of a high-rise system with pressure reducing valves (PRV’s) and their effect on the …
Domestic Water Recirculation Systems Part 4: High Rise Considerations
The last three articles outlined pump selection in domestic water recirculation systems. In general, these systems have low flow and low head pumps. What happens in a high rise with pressure reducing valves (PRV) in the hot water supply? The pressure reducing valve introduces a fixed pressure drop which must be added to the calculations.
Domestic Water Recirculation Systems Part 3: Pressure Drop
The purpose of the domestic water recirculation system is to delivery hot water near a fixture during times when there is no draw. If someone is using hot water in the next room or apartment or process; the hot water is near enough to your fixture so the hot water is delivered in seconds, not minutes.
Plumbing Topic: Domestic Water Recirculation Systems Part 2
Let’s assume the domestic hot water supply is a total length of 1000 ft. That is the entire pipe on all of the floors. Let’s also assume an average of 15 BTU/hr/ft of loss through the supply pipe insulation. Now let’s assume the recirc piping is 300 ft total at an average of 10 BTU/hr/ft of loss. What flow rate is required for a 10 degree ΔT? What flow rate is required for a 5 ΔT?
Case Study: Stabilizing Cooling Tower & Closed Loop Performance at CoCoWalk
Problem Identified CoCoWalk, a large multitenant lifestyle center in Florida, was faced with the following water quality challenges across their cooling tower and closed-loop …
Case Study: Solving Complex Water Quality Issues at the Indiana State Museum & IMAX Theatre
Problem Identified The Indiana State Museum & IMAX Theatre was faced with the following water quality challenges across their closed loop and domestic water …
Case Study: Reducing Maintenance Burden & System Risk in a Closed Loop Chilled Water System
Problem Identified Henniges Automotive was faced with the following familiar water quality challenges in their closed loop chilled water system: Chronic corrosion Sludge buildup Frequent …
Domestic Water Recirculation Systems Part 1: Flow Rate
The R. L. Deppmann Monday Morning Minutes series will focus on the plumbing portion of the new construction and building facility business for the next few months. The topics will be domestic water recirculating systems, pressure booster systems, volume and instantaneous water heaters, and mixing valves. I’ve had 6 job site visits in the last 2 months to help engineers, service contractors, and facility managers solve problems with domestic water recirculating systems. It seems this is a good place to start.
Case Study: Protecting Domestic Hot Water Systems at Iowa State University
Problem Identified Iowa State University (ISU) was faced with the following water quality challenges across their domestic hot water system: Chronic lime-scale buildup Hard, …