• Monday Morning Minute Blog
  • Locate a Wholesaler
  • Careers
  • Contact
  • Customer Portal
    • Customer Portal
    • Portal Help Center
R. L. Deppmann Logo
  • Products
    • Overview
    • Pumps and Accessories
    • Boilers and Water Heaters
      • Water Heater Stock
      • Boiler Stock
    • Hydronic Systems
    • Plumbing Systems
    • Steam and Condensate
    • Variable Frequency Drives (VFDs)
    • Glycol Solutions
    • Snowmelt Designs
  • System Design
    • Overview
    • Project Gallery
    • Selection and Design Tools
  • Water Solutions
  • Contractors
  • Service & Parts
    • Overview
    • Startup and Warranty
    • Parts
    • Service and Maintenance
  • Education
    • Overview
    • Basic Hydronic Blog Articles
    • Training Opportunities
    • Factory Classes
  • About RLD
    • Overview
    • Team Deppmann
    • R.L. Deppmann Locations
    • Careers
    • Community Engagement
    • Press and News

The Bell and Gossett System Syzer and Pump Affinity Laws – to resolve a field problem (Part 2)

RL Deppmann January 26, 2026Pumps, Hydronic System Design, Affinity Laws, Affinity Laws, Troubleshooting, Monday Morning Minutes

Last week we used the Pump Affinity Laws to determine what size the impeller would be trimmed to in an oversized pump. Reducing the speed …

Read More
Pumpstroubleshootingmonday morning minutesaffinity lawshydronic system desgin

The Bell and Gossett System Syzer and Pump Affinity Laws – to resolve a field problem

RL Deppmann January 19, 2026Pumps, Hydronic System Design, Affinity Laws, Affinity Laws, Troubleshooting, Monday Morning Minutes

The Pump Affinity Laws are used to determine the system curve. If we know the point of operation on a pump curve, we can determine …

Read More
Pumpstroubleshootingmonday morning minuteshydronic system designaffinity laws

The Bell and Gossett System Syzer and Pump Affinity Laws

RL Deppmann January 12, 2026Monday Morning Minutes, Pumps, Hydronic System Design, Affinity Laws, Affinity Laws

Hydronic heating system flow rates and pressure drops are related through a series of AFFINITY LAWS. Let’s examine the laws and how to use them …

Read More
Pumpsmonday morning minuteshydronic system designaffinity laws

What is Control Head in Hydronic Variable Speed Pumping?

RL Deppmann February 19, 2024Curves, Affinity Laws, Monday Morning Minutes, Pumps, Hydronic Design, Selection and Specification

Control head is a term used in many different industries. What is the control head in our world of variable speed pumping hydronic and plumbing …

Read More
control headhydronic variable pumpingvariable pumping

Variable Speed Pump Motors and Drives

RL Deppmann February 12, 2024Curves, Efficiency, Speed, Affinity Laws, Affinity Laws, Monday Morning Minutes, Pumps, Hydronic System Design, Selection and Specification

  Danfoss VFD Motor Efficiency Terms Bell & Gossett ECM Pump   Variable speed centrifugal pumps in building heating, cooling, and plumbing systems use a …

Read More
affinity lawsvariable speed pump motorsVariable Speed Drivehydronic system design
heat or cool variable flow system chart
heat or cool variable flow system chart

Developing Variable Speed Pump Curves

RL Deppmann February 5, 2024Monday Morning Minutes, Affinity Laws, Pumps, Hydronic System Design, Selection and Specification, Curves, Efficiency, Speed, Affinity Laws

Most heating and cooling pumps in commercial buildings operate in a variable speed mode. Today, we take your Monday Morning Minutes to explore the variable …

Read More
pumpspump curvesvariable speedaffinity lawsselection and specificationhydronic system design
closed system diagram
closed system diagram

Closed System Curves in HVAC Hydronic Systems

RL Deppmann January 22, 2024Monday Morning Minutes, Pumps, Hydronic System Design, Selection and Specification, Curves, Affinity Laws, Affinity Laws

  A system curve is a graphical representation of how a heating or cooling system flow rate and system head might change as the load …

Read More
hydronic system designaffinity lawsclosed systemsclosed system curves

About Us

Providing quality products and outstanding service to customers in Northern Ohio & Michigan since 1927.
ImageImage

Call Us: 800.589.6120

Navigation

  • Products
  • System Design
  • Contractors
  • Service & Parts
  • Education
  • About RLD
  • Careers

Connect

Connect with us on LinkedIn
Subscribe on YouTube
Cleveland | Detroit | Grand Rapids | Saginaw
Copyright ©2017 R.L. Deppmann. All Rights Reserved
  • Products
    • Overview
    • Pumps and Accessories
    • Boilers and Water Heaters
      • Water Heater Stock
      • Boiler Stock
    • Hydronic Systems
    • Plumbing Systems
    • Steam and Condensate
    • Variable Frequency Drives (VFDs)
    • Glycol Solutions
    • Snowmelt Designs
  • System Design
    • Overview
    • Project Gallery
    • Selection and Design Tools
  • Water Solutions
  • Contractors
  • Service & Parts
    • Overview
    • Startup and Warranty
    • Parts
    • Service and Maintenance
  • Education
    • Overview
    • Basic Hydronic Blog Articles
    • Training Opportunities
    • Factory Classes
  • About RLD
    • Overview
    • Team Deppmann
    • R.L. Deppmann Locations
    • Careers
    • Community Engagement
    • Press and News