• Monday Morning Minute Blog
  • Locate a Wholesaler
  • Careers
  • Contact
  • Customer Portal
    • Customer Portal
    • Portal Help Center
R. L. Deppmann Logo
  • Products
    • Overview
    • Pumps and Accessories
    • Boilers and Water Heaters
      • Water Heater Stock
      • Boiler Stock
    • Hydronic Systems
    • Plumbing Systems
    • Steam and Condensate
    • Variable Frequency Drives (VFDs)
    • Glycol Solutions
    • Snowmelt Designs
  • System Design
    • Overview
    • Project Gallery
    • Selection and Design Tools
  • Water Solutions
  • Contractors
  • Service & Parts
    • Overview
    • Startup and Warranty
    • Parts
    • Service and Maintenance
  • Education
    • Overview
    • Basic Hydronic Blog Articles
    • Training Opportunities
    • Factory Classes
  • About RLD
    • Overview
    • Team Deppmann
    • R.L. Deppmann Locations
    • Careers
    • Community Engagement
    • Press and News
pump selection pump curve
pump selection pump curve

Pump Selection Criteria: Maximum Point on the Curve

Norm Hall May 4, 2018Monday Morning Minutes, Pumps, Selection and Specification

How many times have you, as an engineer, looked at a number of pump curves and passed up a few because you did not like …

Read More

HVAC Hydronic Pumps: Impeller Trimming with a Drive (VFD)

Norm Hall April 9, 2018Monday Morning Minutes, Pumps, Commissioning and Balance, Commissioning and Balance, Pumps

In the last R. L. Deppmann Monday Morning Minute we covered the use of a B&G Triple Duty Valve to set the maximum speed in …

Read More
pumpscommissioning and balancehydronic pumps
proportional balance
proportional balance

HVAC Hydronic Pumps: B&G Triple Duty Valve for Proportional Balance

Norm Hall April 2, 2018Monday Morning Minutes, Pumps, Commissioning and Balance, Commissioning and Balance, Proportional

The ASHRAE Standard 90.1-2013 and the State of Michigan 2015 Energy Code both require the trimming of impellers or reduction in the maximum speed when …

Read More
pumpshvacHVAC Hydronic Pumpsbalance
impeller
impeller

Hydronic Pump Piping and Trim: Pump Suction Energy Levels

Norm Hall March 19, 2018Monday Morning Minutes, Pumps, Selection and Specification, Types

I frown a bit when reading about a product and the only place you find a key tip to avoiding problems is in the troubleshooting …

Read More
closed systemsPipingpumps
whirlpool pump suction
whirlpool pump suction

Hydronic Pump Piping and Trim: The Pump Suction

Norm Hall March 12, 2018Pumps, Selection and Specification, Types, Installation, Monday Morning Minutes

The piping at the suction side of the pump is the most important and, for some engineers and designers, the most misunderstood part of hydronic …

Read More
hydronicPUMP SUCTIONpumps

Hydronic Pump Piping and Trim: Flexible Diffuser Fittings

Norm Hall March 5, 2018Hydronic System Design, Vibration, Expansion and Noise Control, Flexible Connectors, Flexible Connectors, Installation, Monday Morning Minutes, Pumps

Pump installations tend to require a great number of spool pieces to meet the Hydraulic Institute’s and the equipment manufacturers’ recommendations. Before we get into …

Read More
Hydronic Pump Pipingflexible diffuser fittingspumps
pump_suction_sides
pump_suction_sides

Hydronic Pump Piping and Trim: Suction Diffuser Fittings

Norm Hall February 26, 2018Air and Dirt Control, Strainers, Installation, Suction Diffusers, Hydronic, Monday Morning Minutes, Pumps, Valves

Pump suction piping is one of the areas where problems of frequent repair or noise will originate. There is a lot of confusing information out …

Read More
hydronicSuction Diffuser Fittingsvalvespumps
pump_suction_sides
pump_suction_sides

Hydronic Pump Piping and Trim: Suction Side

Norm Hall February 19, 2018Monday Morning Minutes, Pumps, Installation

The pump suction piping and specialties are somewhat simple but can be a cause of headaches if a few simple rules are forgotten. This week …

Read More
pumpshydronicpump installation
Valves
Valves

Hydronic Pump Piping and Trim: Check Valves

Norm Hall February 12, 2018Monday Morning Minutes, Pumps, Valves, Check Valves, Installation

The R. L. Deppmann Monday Morning Minutes reviewed pipe sizing and flexible connectors over the past few weeks. Today we turn our attention to check valves …

Read More

Hydronic Pump Piping and Trim: Should I use a Stainless Steel Flexible Connector?

Norm Hall January 29, 2018Monday Morning Minutes, Pumps, Piping and Installation, Vibration and Expansion Control, Flexible Connectors

Last week, the R. L. Deppmann Monday Morning Minutes introduced reasons why flexible connectors are used on pumps. This week the subject is the stainless …

Read More
  • Page 16 of 24
  • ←
  • 1
  • ...
  • 15
  • 16
  • 17
  • ...
  • 24
  • →

About Us

Providing quality products and outstanding service to customers in Northern Ohio & Michigan since 1927.
ImageImage

Call Us: 800.589.6120

Navigation

  • Products
  • System Design
  • Contractors
  • Service & Parts
  • Education
  • About RLD
  • Careers

Connect

Connect with us on LinkedIn
Subscribe on YouTube
Cleveland | Detroit | Grand Rapids | Saginaw
Copyright ©2017 R.L. Deppmann. All Rights Reserved
  • Products
    • Overview
    • Pumps and Accessories
    • Boilers and Water Heaters
      • Water Heater Stock
      • Boiler Stock
    • Hydronic Systems
    • Plumbing Systems
    • Steam and Condensate
    • Variable Frequency Drives (VFDs)
    • Glycol Solutions
    • Snowmelt Designs
  • System Design
    • Overview
    • Project Gallery
    • Selection and Design Tools
  • Water Solutions
  • Contractors
  • Service & Parts
    • Overview
    • Startup and Warranty
    • Parts
    • Service and Maintenance
  • Education
    • Overview
    • Basic Hydronic Blog Articles
    • Training Opportunities
    • Factory Classes
  • About RLD
    • Overview
    • Team Deppmann
    • R.L. Deppmann Locations
    • Careers
    • Community Engagement
    • Press and News