• Monday Morning Minute Blog
  • Locate a Wholesaler
  • Careers
  • Contact
  • Customer Portal
    • Customer Portal
    • Portal Help Center
R. L. Deppmann Logo
  • Products
    • Overview
    • Pumps and Accessories
    • Boilers and Water Heaters
      • Water Heater Stock
      • Boiler Stock
    • Hydronic Systems
    • Plumbing Systems
    • Steam and Condensate
    • Variable Frequency Drives (VFDs)
    • Glycol Solutions
    • Snowmelt Designs
  • System Design
    • Overview
    • Project Gallery
    • Selection and Design Tools
  • Water Solutions
  • Contractors
  • Service & Parts
    • Overview
    • Startup and Warranty
    • Parts
    • Service and Maintenance
  • Education
    • Overview
    • Basic Hydronic Blog Articles
    • Training Opportunities
    • Factory Classes
  • About RLD
    • Overview
    • Team Deppmann
    • R.L. Deppmann Locations
    • Careers
    • Community Engagement
    • Press and News
element Q
element Q

Packaged Domestic Hot Water Pathogen Mitigation

Norm Hall January 24, 2022Water Quality, Monday Morning Minutes, Air and Dirt Control, Plumbing Systems, Water Heaters, Legionella, Plumbing System Design, Water Quality

Domestic hot water systems should be designed to limit the risk of pathogen issues including Legionnaires Disease. Avoiding risk in the design of these systems …

Read More
LyncDomestic Water Recircwater qualityDomestic Hot Water Recirculation Systemslegionella

Domestic Hot Water: Pathogen Mitigation

Norm Hall January 17, 2022Air and Dirt Control, Plumbing Systems, Monday Morning Minutes, Water Heaters, Legionella, Plumbing System Design, Water Quality

Hot water plumbing system design is a hot topic. The building plumbing design/engineering team is faced with a variety of new products, standards, and codes. …

Read More
Water HeatersASHRAEwater qualityPVI-Water Heaters

Water Heaters & Hard Water: Template Assisted Crystallization

Norm Hall January 10, 2022Plumbing Systems, Monday Morning Minutes, Water Heaters, Water Quality, Water Quality

Hard water is the enemy of plumbing system water heater efficiency and life. Many water heater manufacturer’s warranties are affected by hard water precipitate. We …

Read More
Water Heaterswater qualitytemplate assisted crystallizationHard water
Selection of Air Vents for Hydronic Heating & Cooling HVAC systems
Selection of Air Vents for Hydronic Heating & Cooling HVAC systems

Hydronic System Automatic Air Vents

Norm Hall August 2, 2021Monday Morning Minutes, Air and Dirt Control, Vents and Vacuum Breakers

There are many types of air vents in hydronic heating and cooling HVAC systems. It is not unusual to see an engineered set of drawings …

Read More
Bell & Gossett Hoffman Specialty Water Vent Series
Bell & Gossett Hoffman Specialty Water Vent Series

Selecting Air Vents For Hydronic Systems With Glycol

Norm Hall July 26, 2021Monday Morning Minutes, Air and Dirt Control, Vents and Vacuum Breakers

Sometimes simple things can slow you down in the design of hydronic heating and cooling systems. Air vents for use in water and glycol systems …

Read More
TTXR Cooling Tower Basins
TTXR Cooling Tower Basins

Tired of Water Quality Issues with Cooling Tower Basins?

Norm Hall March 9, 2020Hydronic System Design, Glycol and Water Quality, Air and Dirt Control, Cooling, Cooling Towers, Sediment Separators, Cooling Towers, Sediment Separators, Monday Morning Minutes

What’s lurking in your traditional open cooling tower basin? Today, there is a growing concern about the sediment build-up, algae growth, and bacteria growth in …

Read More
separator on tower pump
separator on tower pump

Primary – Secondary Sediment Separator Piping in Variable Flow Cooling Tower/Condenser Water Systems

Norm Hall February 24, 2020Monday Morning Minutes, Hydronic System Design, Glycol and Water Quality, Air and Dirt Control, Cooling, Cooling Towers, Sediment Separators, Cooling Towers, Sediment Separators

The last R. L. Deppmann Monday Morning Minutes offered suggestions for the use of a Griswold sediment separator in a variable flow tower system. The …

Read More
variable flow cooling tower/condenser water systems
variable flow cooling tower/condenser water systems

Sediment Separators in Variable Flow Cooling Tower/Condenser Water Systems

Norm Hall February 17, 2020Monday Morning Minutes, Glycol and Water Quality, Air and Dirt Control, Sediment Separators, Cooling Towers, Sediment Separators

A sediment separator will remove particles down to 20 microns or lower when properly sized and applied. This makes them a great choice in open …

Read More
pump_suction_sides
pump_suction_sides

Hydronic Pump Piping and Trim: Suction Diffuser Fittings

Norm Hall February 26, 2018Installation, Suction Diffusers, Hydronic, Monday Morning Minutes, Pumps, Valves, Air and Dirt Control, Strainers

Pump suction piping is one of the areas where problems of frequent repair or noise will originate. There is a lot of confusing information out …

Read More
hydronicSuction Diffuser Fittingsvalvespumps
New LPD Strainer Design Saves 40% in Energy Usage vs Basket Strainers
New LPD Strainer Design Saves 40% in Energy Usage vs Basket Strainers

New LPD Strainer Design Saves 40% in Energy Usage vs Basket Strainers

Norm Hall April 10, 2017Monday Morning Minutes, Air and Dirt Control, Strainers

What if a product could save 40% in energy usage without increasing the cost in a hydronic or steam system? This week’s R L Deppmann …

Read More
  • Page 2 of 3
  • ←
  • 1
  • 2
  • 3
  • →

About Us

Providing quality products and outstanding service to customers in Northern Ohio & Michigan since 1927.
ImageImage

Call Us: 800.589.6120

Navigation

  • Products
  • System Design
  • Contractors
  • Service & Parts
  • Education
  • About RLD
  • Careers

Connect

Connect with us on LinkedIn
Subscribe on YouTube
Cleveland | Detroit | Grand Rapids | Saginaw
Copyright ©2017 R.L. Deppmann. All Rights Reserved
  • Products
    • Overview
    • Pumps and Accessories
    • Boilers and Water Heaters
      • Water Heater Stock
      • Boiler Stock
    • Hydronic Systems
    • Plumbing Systems
    • Steam and Condensate
    • Variable Frequency Drives (VFDs)
    • Glycol Solutions
    • Snowmelt Designs
  • System Design
    • Overview
    • Project Gallery
    • Selection and Design Tools
  • Water Solutions
  • Contractors
  • Service & Parts
    • Overview
    • Startup and Warranty
    • Parts
    • Service and Maintenance
  • Education
    • Overview
    • Basic Hydronic Blog Articles
    • Training Opportunities
    • Factory Classes
  • About RLD
    • Overview
    • Team Deppmann
    • R.L. Deppmann Locations
    • Careers
    • Community Engagement
    • Press and News