• Monday Morning Minute Blog
  • Locate a Wholesaler
  • Careers
  • Contact
R. L. Deppmann Logo
  • Products
    • Overview
    • Pumps and Accessories
    • Boilers and Water Heaters
      • Water Heater Stock
      • Boiler Stock
    • Hydronic Systems
    • Plumbing Systems
    • Steam and Condensate
    • Variable Frequency Drives (VFDs)
    • Glycol Solutions
    • Snowmelt Designs
  • System Design
    • Overview
    • Project Gallery
    • Selection and Design Tools
  • Water Solutions
  • Contractors
  • Service & Parts
    • Overview
    • Startup and Warranty
    • Parts
    • Service and Maintenance
  • Education
    • Overview
    • Basic Hydronic Blog Articles
    • Training Opportunities
    • Factory Classes
  • About RLD
    • Overview
    • Team Deppmann
    • R.L. Deppmann Locations
    • Careers
    • Community Engagement
    • Press and News
temperatures
temperatures

Heat Pump Water Heaters: Temperatures & Storage (Part 4)

Norm Hall August 22, 2022Water Heaters, Plumbing System Design, Electric, Heat Pump Water Heaters, Monday Morning Minutes, Heat Pump Water Heaters

Commercial heat pump water heaters using R-744 (CO2) refrigerant operate best when attention is paid to the piping and storage tank arrangement. Today, in part …

Read More
Expansion TanksWater HeatersPipingPumpsTanksNorm Hall
lightbulb
lightbulb

Carbon Reduction is the Dream. Here’s How to Make it a Good One.

Norm Hall May 23, 2022Hydronic Design, Decarbonzation, Decarbonization, Plumbing System Design

Carbon reduction in building design is critical to the lifestyle of our future generations. Most engineers and their owner clients understand the concerns and welcome …

Read More
decarbonizationHydronicsPumpsNorm Hallhydronic systems

Primary-Secondary Variable Heating Systems: Should I Pump Into the Boiler or away from It?

Norm Hall April 25, 2022Boilers, Hydronic Design, Primary Secondary Piping, Primary Variable, Monday Morning Minutes

Previously, the R. L. Deppmann Monday Morning Minutes looked at pump location in a primary-variable boiler heating system. We made a very definitive statement about …

Read More
hydronic systemsprimary-secondary pipingBoilersHydronicsPumpsvariable speed
aegis w swing tank
aegis w swing tank

Heat Pump Water Heaters – Will They Save the World?

Norm Hall March 7, 2022Pumps, Water Heaters, Pool Heaters, Gas Fired, Electric, Monday Morning Minutes

Decarbonization and Electrification are two terms which may bring both fear and hope to plumbing engineers and gas fired water heater manufacturers. The hope is …

Read More
LyncWater HeatersPumpsTanksNorm Hall
indoor swimming pool
indoor swimming pool

B&G Pumps in Chlorinated Swimming Pool Applications

Norm Hall December 6, 2021Monday Morning Minutes

We often get questions about using Bell & Gossett pumps in institutional and commercial chlorinated water swimming pool applications. Here are a few suggestions about …

Read More
PumpsBell and GossettBell & Gossettflow rate
epact
epact

What are ECM Pumps & ECM Smart Pumps

Norm Hall October 23, 2017Monday Morning Minutes, Pumps, ECM, Variable Speed, ECM

Last week, I defined ECM motors and how they differ from standard PSC and induction motors. We recently had a customer call who was very …

Read More
PumpsECMvariable speed
Examples of Pump Cavitation
Examples of Pump Cavitation

Pump Cavitation

Ron Bohnak March 15, 2017Service Tip of the Month

“Pump cavitation is, by definition, the formation and subsequent collapse or implosion of vapor bubbles in a pump. This usually occurs when gaseous bubbles are …

Read More
Pumpscavitationpump cavitation
R.L. Deppmann Water Test Sample Kit
R.L. Deppmann Water Test Sample Kit

How Water Quality and Seal Selection Affect Hydronic Systems

Scott Tilley November 15, 2016Service Tip of the Month

The water quality in hydronic systems directly affects the performance and life expectancy of the components in the systems. Total dissolved solids (TDS) and pH …

Read More
HydronicsPumpswater qualityseals
Pump Tag with Fields Labeled
Pump Tag with Fields Labeled

How to Determine Impeller Size with Shut-off Head

Kevin Paszt September 15, 2016Service Tip of the Month

Here is a quick way to determine impeller size from the No Flow point on the pump curve. Tools needed: 1) Pump curve. Select the …

Read More
Pumps
STM - June 2016 picture - B&G Coupler Assembly_118709
STM - June 2016 picture - B&G Coupler Assembly_118709

Coupler and Motor Bracket

RL Deppmann June 15, 2016Service Tip of the Month

In this service tip of the month, we discuss small 3-piece circulators and the importance of using the correct coupler and motor mounts to ensure continued …

Read More
Pumps
  • Page 5 of 6
  • ←
  • 1
  • ...
  • 4
  • 5
  • 6
  • →

About Us

Providing quality products and outstanding service to customers in Northern Ohio & Michigan since 1927.
ImageImage

Call Us: 800.589.6120

Navigation

  • Products
  • System Design
  • Contractors
  • Service & Parts
  • Education
  • About RLD
  • Careers

Connect

Connect with us on LinkedIn
Subscribe on YouTube
Cleveland | Detroit | Grand Rapids | Saginaw
Copyright ©2017 R.L. Deppmann. All Rights Reserved
  • Products
    • Overview
    • Pumps and Accessories
    • Boilers and Water Heaters
      • Water Heater Stock
      • Boiler Stock
    • Hydronic Systems
    • Plumbing Systems
    • Steam and Condensate
    • Variable Frequency Drives (VFDs)
    • Glycol Solutions
    • Snowmelt Designs
  • System Design
    • Overview
    • Project Gallery
    • Selection and Design Tools
  • Water Solutions
  • Contractors
  • Service & Parts
    • Overview
    • Startup and Warranty
    • Parts
    • Service and Maintenance
  • Education
    • Overview
    • Basic Hydronic Blog Articles
    • Training Opportunities
    • Factory Classes
  • About RLD
    • Overview
    • Team Deppmann
    • R.L. Deppmann Locations
    • Careers
    • Community Engagement
    • Press and News