• Monday Morning Minute Blog
  • Locate a Wholesaler
  • Careers
  • Contact
R. L. Deppmann Logo
  • Products
    • Overview
    • Pumps and Accessories
    • Boilers and Water Heaters
      • Water Heater Stock
      • Boiler Stock
    • Hydronic Systems
    • Plumbing Systems
    • Steam and Condensate
    • Variable Frequency Drives (VFDs)
    • Glycol Solutions
    • Snowmelt Designs
  • System Design
    • Overview
    • Project Gallery
    • Selection and Design Tools
  • Water Solutions
  • Contractors
  • Service & Parts
    • Overview
    • Startup and Warranty
    • Parts
    • Service and Maintenance
  • Education
    • Overview
    • Basic Hydronic Blog Articles
    • Training Opportunities
    • Factory Classes
  • About RLD
    • Overview
    • Team Deppmann
    • R.L. Deppmann Locations
    • Careers
    • Community Engagement
    • Press and News
BTUH Heat Exchanger
BTUH Heat Exchanger

Bell & Gossett SU Heat Exchangers – Sleuthing the BTUH Capacity (Part 2)

Norm Hall October 29, 2018Monday Morning Minutes, Heat Exchangers, Shell and Tube, Identification

As I noted in our last R. L. Deppmann Monday Morning Minutes (Part 1), an engineer in the Detroit area asked a question we get …

Read More
photo of heater
photo of heater

Bell & Gossett SU Heat Exchanger – Estimation of BTUH Capacity (Part 1): Field Identification

Norm Hall October 22, 2018Monday Morning Minutes, Heat Exchangers, Shell and Tube, Identification

An engineer in the Detroit area asked a question we get asked every month of every year. The way he asked it caught my attention. …

Read More
Bell & Gossett 1510 Pump Model
Bell & Gossett 1510 Pump Model

Bell & Gossett 1510 Pump Model Numbers: Field Estimation of Flow Rate

Norm Hall October 15, 2018Monday Morning Minutes, Pumps, Identification

Oftentimes an engineer or contractor is contracted to remodel or add to an existing building. During the site visit, they find a pump tag with …

Read More
Bell and Gossettflow ratepumpsb&g

Break The Tie! Preso Ellipse Flow Meters for HVAC Hydronic Mains

Norm Hall September 17, 2018Monday Morning Minutes, Flow Measurement

The balance contractor often has a tough job when completing the flow balance of an HVAC hydronic heating or cooling system. Today’s engineering documents tend …

Read More
flow meterflow measurement
pressure independent control valve
pressure independent control valve

Balancing HVAC Hydronic Systems Part 5: Pressure Independent Control Valve (PICV)

Norm Hall September 10, 2018Monday Morning Minutes, Valves, Balance

Air side terminal units have used pressure independent control valves for a long time. These valves, also called PICV, are still relatively new in hydronics. …

Read More
Graph Showing Control Curve and Area
Graph Showing Control Curve and Area

Variable Speed Pump Control & Automatic Balance Valves : Part 4

Norm Hall September 3, 2018Monday Morning Minutes, Valves, Balance

A few weeks ago in the R. L. Deppmann Monday Morning Minutes (MMM) part 3 of this series, we showed that direct return systems with …

Read More
Automatic Flow Control
Automatic Flow Control

Balancing HVAC Hydronic Systems Part 4: Automatic Flow Limiting

Norm Hall August 27, 2018Monday Morning Minutes, Valves, Balance

Last week, the R. L. Deppmann Monday Morning Minutes (MMM) showed the advantages and disadvantages of manual balance valves. Today, we continue with automatic balance …

Read More
hammer
hammer

Balancing HVAC Hydronic Systems Part 3: Flow Measurement Valves

Norm Hall August 20, 2018Monday Morning Minutes, Flow Measurement, Commissioning and Balance, Hydronic System Design, Test and Balance, Flow Tolerance

The flow balance of a hydronic system is a critical component in the commissioning of an HVAC hydronic system. The common balance and flow measurement …

Read More
control valve simple hydronic system
control valve simple hydronic system

Balancing HVAC Hydronic Systems Part 2: Control Valves vs. Balance Valves

Norm Hall August 13, 2018Flow Tolerance, Balance, Monday Morning Minutes, Valves, Commissioning and Balance, Hydronic System Design, Test and Balance

There are some engineers who challenge the use of balancing valves at all in hydronic systems. If the control valve throttles the flow to satisfy …

Read More
flow tolerance hvac hydronic system
flow tolerance hvac hydronic system

Balancing HVAC Hydronic Systems Part 1: Flow Tolerance

Norm Hall August 6, 2018Monday Morning Minutes, Commissioning and Balance, Hydronic System Design, Test and Balance, Flow Tolerance

The flow tolerance of a hydronic system is a critical component in the commissioning of an HVAC hydronic system. Should the balance report match the …

Read More
  • Page 35 of 60
  • ←
  • 1
  • ...
  • 34
  • 35
  • 36
  • ...
  • 60
  • →

About Us

Providing quality products and outstanding service to customers in Northern Ohio & Michigan since 1927.
ImageImage

Call Us: 800.589.6120

Navigation

  • Products
  • System Design
  • Contractors
  • Service & Parts
  • Education
  • About RLD
  • Careers

Connect

Connect with us on LinkedIn
Subscribe on YouTube
Cleveland | Detroit | Grand Rapids | Saginaw
Copyright ©2017 R.L. Deppmann. All Rights Reserved
  • Products
    • Overview
    • Pumps and Accessories
    • Boilers and Water Heaters
      • Water Heater Stock
      • Boiler Stock
    • Hydronic Systems
    • Plumbing Systems
    • Steam and Condensate
    • Variable Frequency Drives (VFDs)
    • Glycol Solutions
    • Snowmelt Designs
  • System Design
    • Overview
    • Project Gallery
    • Selection and Design Tools
  • Water Solutions
  • Contractors
  • Service & Parts
    • Overview
    • Startup and Warranty
    • Parts
    • Service and Maintenance
  • Education
    • Overview
    • Basic Hydronic Blog Articles
    • Training Opportunities
    • Factory Classes
  • About RLD
    • Overview
    • Team Deppmann
    • R.L. Deppmann Locations
    • Careers
    • Community Engagement
    • Press and News