Selection and Design Tools
Equipment Selection Solutions for Your Project All in One Spot!
R. L. Deppmann represents a vast array of manufacturers in the industry, which means that we have access to equipment selection software that can’t be found everywhere. Whether you want to make your own selection, have your selection verified, or have someone to help you choose your heating, cooling and plumbing equipment—the experts at R. L. Deppmann are here to support you. NOTE: Many of the links on this page have mobile-friendly versions of the software.
Equipment Design & Selection Tools
Plumbing System - Selection Tools
Hydronic System - Design Tools
Hydronic System - Selection Tools
- B&G ESP-Systemwize pump selection (Bell & Gossett)
- Systemwize: Introduction & Selecting a New System Video by Bell & Gossett
- Systemwize Pump Selection: How to Pick A Pump Video by Bell & Gossett
- Systemwize: Introduction & Selecting a New System Video by Bell & Gossett
- Systemwize Pump Selection: How to Pick A Pump Video by Bell & Gossett
- ESP-Parts selection (Bell & Gossett)
- ESP-Tanks - Expansion Tanks (Bell & Gossett)
- ESP-Thermal - Plate Heat Exchanger Selection (Bell & Gossett)
- ESP-U Tube Heat Exchanger Selection (Bell & Gossett)
- Circuit Setter selection guide (R. L. Deppmann)
- Triple duty valve selection guide (R. L. Deppmann)
- Radiant Design Software (Mr. Pex)
- Tank Selection Software (Wessels)
- Product Selector (Griswold)
- Cooling Tower Selection Software (Tower Tech)
- Vertical Pump Selection Software (Vertiflo Pump)
- Useful formulas for Hydronic Systems (R. L. Deppmann)
- 1140 self-contained temperature regulators (Hoffman)
- Boiler Selection Chart (Bryan Boiler)
- Commercial Selection Guide (Burnham Boiler)
- Engineering Selection Software (Danfoss)
Hydronic System - Technical Manuals
- Air Management Sizing and Installation Instructions for Hydronic Heating/Cooling Systems (TEH 1196B)
- Booster Pump Service Manual & Troubleshooting Guide (HS 105 SM)
- Circuit Setter Valve Balance Procedure (TEH 985A)
- Cooling Tower Pumping and Piping (TEH 1209A)
- CounterPoint How Hydronic System Components Really Work (FHD 501A)
- Domestic Water Pressure Booster Design (TEH 1096A)
- Equipment Room Piping Practice (TEH 1275A)
- Hydronic System Design with the Bell & Gossett System Syzer (TEH 908A)
- Hydronic System Types (TEH 471A)
- Little Red Schoolhouse - Seminars for HVAC & Plumbing Systems Design and Service (BG-LRS-100A)
- Parallel and Series Pump Application (TEH 1109A)
- Primary Secondary Pumping Application Manual (TEH 775A)
- Principals of Centrifugal Pump Construction (TEH 1166B)
- Pump & System Curve Data for Centrifugal Pump Selection and Application (TEH 375A)
- Pump Selection for Building Service Systems (TEH 1208A)
- System Syzer Calculator (TEH 175A)
- Variable Primary Flow Systems (TEH 910A)
- Variable Speed/Variable Volume Pumping Fundamentals (TEH 685)
Steam System - Design Tools
- Hoffman Steam Pipe Size Selector
- Hoffman Steam Loss Calculator
- Hoffman Flash Steam Calculator
- Hoffman Condensate Pipe Size Selector
- DriCalc for Selection Program (Dristeem)
- Energy Calc Software (Dristeem)
- Loadcalc Software (Dristeem)
- Useful formulas for Steam Systems (R. L. Deppmann)
Steam System - Selection Tools
- Steam 2000 pressure reducing valve (Hoffman Specialty)
- 1140 Self-Contained Temperature Regulators (Hoffman Specialty)
- Steam Trap Selection (Hoffman Specialty)
- Valve Size Selection Software (Dristeem)
- Deaerator Sizing Program (Bryan Boiler)
- Boiler Selection Chart (Bryan Boiler)
Steam System - Technical Manuals
- Basic Steam Pipe Sizing Charts (TES 378)
- Domestic Pump Product Application and Sizing Manual (TES 676B)
- Hoffman Specialty Steam Regulating Valves Manual (TES 492B)
- Steam Heat Exchangers (TES 485B)
- Steam Heating Application Manual (TES 375A)
CAD Tools
Many of our manufacturers have CAD drawings and details of their products. They have everything from 2D CAD format to Revit files. Visit our Hydronic, Steam and Condensate, and Plumbing system pages to link directly to the file you need.