Domestic Water Recirculation Systems Part 6: High Rise Considerations

RL DeppmannMonday Morning Minutes, Plumbing System Design, Domestic Water Recirculation, Balancing, High Rise Systems

High Rise Considerations The last article, part 5, showed an example of a high rise system with pressure reducing valves (PRVS) and the importance of the correct setting of the balance valves. The example we used showed balance valves with as much as 18 PSIG across them at a low flow. When a design starts to incorporate