Why RL Deppmann for Your Water Heater?
Whatever your needs are for water heaters, R L Deppmann offers a high level of technical service, a broad product line of reputable products, and engineering expertise.
- Extensive offering of high-quality products from trusted manufacturers to fit your needs
- Engineering, technical, and application knowledge to save you time and lower your risk
- Installation tips and troubleshooting assistance from our field techs and inside service team
- The expertise to help you choose the correct product for your project
Check Availability of R.L. Deppmann Stock Here:
Which Gas Fired Water Heater Type Do I Need?
Answer a Few Questions to Find Out
Gas and Propane-Fired Tank Type Condensing Storage Water Heaters
Tank type water heaters have a high recovery burner coupled with some storage to handle larger peak demands or dump loads. R. L. Deppmann offers PVI and Bock brands. They look like your residential water heater but the similarities in our brands end there.
Additional Information
Looking for technical design information on gas-fired water heaters?
Which one should I choose?
| Brand | Warranty | Efficiency | 1st cost | Lifetime Cost |
|---|---|---|---|---|
| PVI | 15-25 years | 97% | $$$ | $$$ |
| Bock | 5 years | 99% | $$ | $$$$$ |
| Many competitors | 1-3 years | 95% | $ to $$$ | $$$$$$ |
Two fine quality brands of products which serve different needs. The choices are lower first cost vs. lower lifetime costs.
Capacity Ranges for Gas-Fired Tank Type Water Heaters
| Brand | Model | Capacity MBH | Storage Gallons | Efficiency | Width |
|---|---|---|---|---|---|
| PVI | Turbopower 96 | 500-1600 | 300-1500 | 97.5% | 64"-81" |
| PVI | Conquest 130 | 399-1000 | 130 | 97% | 34" |
| PVI | Conquest 100 | 199-300 | 100 | 97% | 28" |
| Bock | OPT | 125-500 | 99-125 | 99% | 28"-32" |
PVI by WATTS Gas-Fired Tank Type Condensing Water Heaters
Features / Highlights
- AquaPLEX® dual metal SS heat exchanger and tank engineered for domestic hot water heating
- 15 or 25 year pro-rated warranty depending on the model
- Single Pass heat exchangers increase efficiency
- TurboPower has replaceable burner assembly
- No anodes to replace
- Internally-controlled circulator pump reduces scaling
- ASME tank is standard
- Designed with controls for automatic disinfection
- Choice of venting (SS, PVC, CPVC, Poly)
- Vent sensor safety system matches vent material
- Low life-cycle cost
- Turbopower96 has replacement heat exchanger and burner assembly

Additional Information
Learn more about PVI Tank Type HeatersBock OptiTHERM Gas-Fired Tank Type Condensing Water Heaters
Features / Highlights
- Glass-fused-to-steel water tank and heat exchanger
- 5-year limited warranty better than most competitors
- No anodes to replace
- Dual TurboFlue® heat exchanger
- ASME tank is available on most models
- Choice of venting (SS, PVC, CPVC, Poly)
Gas-Fired Tank Type Non-Condensing Storage Water Heaters
Today’s commercial and institutional buildings use high-efficiency condensing boilers. There are some replacement applications for older technology.
| Brand | Model | Capacity MBH | Storage Gallons |
|---|---|---|---|
| PVI | Turbopower | 199-2000 | 150-1500 |
| PVI | Maxim | 270-800 | 250 |
| PVI | Maxim | 199-520 | 125 |
| Bock | Energy Saver | 76-1500 | 30-119 |
| Bock | EZ-Fit | 99-199 | 75-100 |
Gas and Propane Fired Tankless Condensing Water Heaters
Tankless water heaters combine the high efficiency of condensing water heaters with the immediate availability of hot water. The storage inside of a tankless heater is very minimal and used to protect people from temperature fluctuations due to immediate load changes. Tankless design efficiency is superior to instantaneous designs, particularly at low and recirculation loads.
See the Dual Fuel section of the website for combination electric and gas models
Capacity Ranges for Tankless Water Heaters
| Brand | Model | MBH Input | Recovery GPH/GPM 40°F - 140°F | Volume Gallons | Efficiency |
|---|---|---|---|---|---|
| Aerco Innovation | INN 1350 | 1350 | 1572 / 26.2 | 19.9 | 96% |
| Aerco Innovation | INN 1060 | 1060 | 1224 / 20.4 | 22 | 95% |
| Aerco Innovation | INN 800N | 800 | 924 / 15.4 | 25.3 | 94% |
| Aerco Innovation | INN 600N | 625 | 696 / 11.6 | 25.3 | 93% |
| PVI Brigade | 20L 25 RGC | 199 | 233 | 25 | 97.5% |
Aerco Innovation Tankless Condensing Water Heaters
Features / Highlights
- AERguard stainless steel helical firetube heat exchanger assembly is thermal shockproof and scale resistant
- Warranty: 10 year on pressure vessel and heat exchanger. 2 year on the controller, 1 year balance of trim
- Small footprint and fits through 36” door
- Available Edge controller with diagnostics and mobile application
- Modulating up to 27:1 turndown with ±4⁰F accuracy
- Set points up to 190⁰F
- Sequence up to 16 water heaters in parallel
- Up to 99% efficiency
- Low life-cycle cost
- ASME Construction
PVI Brigade Tankless Condensing Water Heaters
Features / Highlight
- AquaPLEX® duplex SS heat exchanger and tank engineered for domestic hot water heating
- Full 6 year warranty
- Very small footprint -16” x 23” floor space
- Set points up to 185⁰F
- Modulating up to 7:1 turndown
- Sequence up to 6 water heaters in parallel
- Up to 99% efficiency

Additional Information
More information on PVI BrigadeGas and Propane Fired Condensing Volume Water Heaters
Volume water heaters are designed with a separate heater and tank. The water heater has little volume and requires a specific range of flow rates. To accomplish this, a Bell & Gossett all bronze or SS pump is used between the tank and the heater.
R. L. Deppmann offers NTI, Thermal Solutions, Aerco, and PVI brands.

Capacity Ranges for Gas Fired Volume Water Heaters
| Brand | Model | Capacity MBH |
|---|---|---|
| Thermal Solutions | AMPW | 400-3,920 |
| NTI | Lx-WH | 199-300 |
NTI Lx-WH Gas Fired Condensing Commercial Volume Water Heaters
Features/Highlights
- Touch screen controls
- Modulating 8:1 turndown
- Stainless steel heat exchanger
- Up to 96% efficiency
Volume water heaters require a separate tank and circulating pump. The tank are shown in the tank section of this webpage. The following is the suggested pump to use assuming no more than 5 feet of pipe valve and fitting losses.
| NTI Lx-WH Model | MBH1 | Recovery GPH1 | Min Pump GPM | Suggest Pipe Size2 | Constant Speed Circulator3 | ecm Smart Pump3 |
|---|---|---|---|---|---|---|
| 200 | 199 | 229 | 16 | 1-1/2" | PL-36B-1/6HP | XL-N-36-45 |
| 300 | 275 | 317 | 24 | 2" | PL-55B-2/5HP | XL-N-36-45 |
| 400 | 399 | 460 | 32 | 2" | 60-Be606-1/2HP | XL-N-55-45 |
| 500 | 500 | 576 | 40 | 3" | 60-Be6134-3/4HP | XL-N-65-130 |
| 600 | 600 | 691 | 48 | 3" | 60-Be6133-3/4HP | XL-N-65-130 |
| 700 | 700 | 806 | 56 | 3" | 60-Be609-3/4HP | XL-N-65-130 |
| 800 | 800 | 922 | 64 | 4" | 60-Be614-1HP | XL-N-65-130 |
(2) Based on velocity less than 4 FPS
(3) Based on Bell & Gossett with 5 ft. pipe and valve PD allowance
(4) BTO Bronze pump with equivalent impeller
Thermal Solutions AMPW Gas Fired Condensing Commercial Volume Water Heaters
Features/Highlights
- Small footprint and stackable
- Dual fuel switchable – Nat. gas and propane
- Touch control with self-guided diagnostics.
- Modulating 5:1 turndown
- Sequence up to 8 water heaters in parallel
- 316L Stainless steel heat exchanger
- Up to 98% efficiency
| Thermal Soluti0ns AMPW Model | MBH1 | Recovery GPH1 | Min Pump GPM | Suggest Pipe Size2 | Constant Speed Circulator3 | ecm Smart Pump3 |
|---|---|---|---|---|---|---|
| AMPW-1000 | 980 | 1176 | 99 | 4" | 60-Be611-3/4HP | XL-N-40-200 |
| AMPW-1250 | 1225 | 1485 | 99 | 4" | 60-Be611-3/4HP | XL-N-40-200 |
| AMPW-1500 | 1470 | 1782 | 110 | 4" | 60-Be627-1-1/2HP | XL-N-40-200 |
| AMPW-2000 | 1960 | 2376 | 138 | 4" | 60-Be627-1-1/2HP | XL-N-40-200 |
| AMPW-2500 | 2450 | 2970 | 214 | 6" | 92SV-1-3HP | XL-N-40-275 |
| AMPW-3000 | 2940 | 3564 | 214 | 6" | 92SV-1-3HP | XL-N-40-275 |
| AMPW-3500 | 3430 | 4158 | 214 | 6" | 92SV-1-3HP | XL-N-40-275 |
| AMPW-4000 | 3920 | 4752 | 214 | 6" | 92SV-1-3HP | XL-N-40-275 |
(2) Based on velocity less than 4 FPS
(3) Based on Bell & Gossett with 5 ft. pipe and valve PD allowance
(4) BTO Bronze pump with equivalent impeller
(5) Flow and pump selection based on 5-12 grains gpg hardness
Contact RLD for other conditions.
Helpful tips, delivered to your inbox every Monday.
Electric Water Heaters
RL Deppmann joins the electrification effort with a wide variety of electric water heaters to fit multiple codes, service requirements, and budgets. In general, electric water heaters are 98% efficiency or higher. Most models have many options available to fit your project requirements.
See the Dual Fuel section of the website for combination electric and gas models.
Capacity Ranges for Electric Water Heaters
| Brand and Model | GPH Recovery 40°F to 100°F | kW Range | Storage Gallons | Tank Type |
|---|---|---|---|---|
| PVI Durawatt Spec | 70-590 | 18-144 | 119-4500 | Horizontal ASME |
| PVI Durawatt Std | 70-590 | 18-144 | 119-750 | Vertical ASME |
| Bock Electritherm CE | 54-217 | 13.5-54 | 50-119 | Vertical Non-code |
| Bock LVE Large KW Electric | 49-1476 | 12-360 | 150-2500 | Vertical ASME |
| Cemline H-EHB Electric | 49-984 | 12-240 | 120-6080 | Horizontal ASME |
| Cemline V-EHB Electric | 49-984 | 12-240 | 40-3920 | Vertical ASME |
| Bock Commercial Electric | 25-223 | 6-54 | 50-119 | Vertical ASME |
| Bock LCE nDurance | 6-24 | 1.5-6 | 6-20 | Shel Non-code |
| NTI Compact Electric | 6.8 | 1.44 | 2.7-7 | Wall Mtd. Non-code |
PVI Durawatt® Water Heater
Features/Highlights
- AquaPLEX® duplex SS heat exchanger and tank engineered for domestic hot water heating
- 25-year warranty on tank and elements
- Incoloy or copper sheathed heating elements std w/non-ferrous waterside connections. Electro-polished Incoloy available
- Elements individually mounted with flanged bronze connections
- Modbus connections: setpoint control, temperature, and alarms. BACnet gateway available
- ASME construction
Cemline EHB Water Heater
- Stonesteel cement lined steel tank
- 5-year warranty on the lining
- Incoloy or copper sheathed heating elements
- Elements individually mounted with flanged non-ferrous connections
- Modbus connections: setpoint control, temperature, and alarms. BACnet gateway is available
- ASME construction
Bock ElectriTHERM, Commercial Electric CF and Large kW LVE Water Heater
Features/Highlights
- Glass-lined steel tank
- 3-year warranty on ASME product
- Incoloy sheathed heating elements
- Screw-in elements on CF and ElectriTHERM
- BMS connections available
- ElectriTherm is non-code and CF and LVE are ASME construction
Whether you have a question about the product or want information on product availability and pricing, we've got you covered.
Indirect Steam Water Heaters
Which Indirect Steam Water Heater Type Do I Need?
Answer a Few Questions to Find Out
Capacity Ranges for Indirect Steam Water Heaters
| Water Heater Double Wall | Brand and Model | Flow Rate or Recovery 40°F-140°F | Storage Gallons |
|---|---|---|---|
| Instantaneous | Aerco SWDW | 0-150 GPM** | None |
| Instantaneous | Cemline SEH-D | 0-120 GPM | None |
| Instantaneous | PVI Cobrex-CCX | 20-120 GPH | None |
| Semi-Instantaneous | Cemline SSH-D | 0-200 GPM | 30-60 |
| Semi-Instantaneous | PVI Cobrex Semi-ISD | 8-59 GPM | 10-80 |
| Semi-Instantaneous | PVI Quickdraw Semi QD-ISD | 0-74 GPM | 50-100 |
| Storage | Cemline SWH-D | 148-12,220 GPH | 100-6,080 |
| Storage | PVI Cobrex Storage QSD | 0-8,425 GPH | 250-1,000 |
| Storage | PVI Quickdraw Storage QS-ISD | 200-3,200 GPH | 150-900 |
| Water Heater Single Wall | Brand and Model | Flow Rate or Recovery 40°F-140°F | Storage Gallons |
|---|---|---|---|
| Instantaneous | Aerco B+II | 0-125 GPM*** | None |
| Instantaneous | Cemline SEH-S | 0-120 GPM | None |
| Semi-Instantaneous | Cemline SSH-S | 0-200 GPM | 30-60 |
| Storage | PVI Quickdraw Storage QS-IS | 200-3,200 GPH | 150-900 |
| Storage | Cemline SWH-S | 148-12,220 GPH | 100-6,080 |
| Semi-Instantaneous | PVI Quickdraw Semi QD-IS | 0-74 GPM | 50-100 |
Aerco Instantaneous SWDW Double Wall & B+II Single Wall Water Heater
Features/Highlights
- On B+II, 20-year warranty on pressure vessel and demand anticipator, 10-year complete heat exchanger, 1-year balance of package
- All Stainless, TFE, Copper or Copper Alloy Wetted Surfaces
- Main steam trap and optional steam supply drip trap and strainers shipped loose
- Aerco monitoring system for ±4⁰F temperature control under normal load changes
- UL Listed double wall or single wall models
- Modbus connections available as option
- ASME construction
Cemline Instantaneous SEH-D Double Wall and SEH-S Single Wall Water Heater
Features/Highlights
- 5-year warranty on pressure vessel, 1-year balance of package
- 316L SS shell, copper tubes, copper-lined tube sheet, copper bundle wrapper
- Pre-piped main steam trap and steam supply drip trap and strainers
- Electronic, pneumatic, or self-contained steam control valves
- Double-wall or single-wall models
- Modbus connections standard with Cem-trol II controller
- Integral circulator
- Includes insulation and jacketing
- ASME construction
Cemline SSH Semi-Instantaneous and SWH Storage Type Water Heaters
Features / Highlights
- 5-year warranty on pressure vessel, 1-year balance of package
- 316L SS tank, copper tubes, copper lined tube sheet, copper bundle wrapper for SSH only
- Great for non-condensing applications with boiler water 160⁰F or more
- Electronic or pneumatic control valve pre-piped
- Double wall or single wall models
- Modbus connections standard with Cem-trol II controller
- Integral circulator
- Includes insulation and jacketing
- ASME construction

Additional Information
Cemline SSH semi-instantaneous water heater
Cemline SWH storage type water heater
PVI Cobrex CCX Instantaneous Double Wall Water Heater
Features / Highlights
- 3-year warranty on heat exchanger, 1-year balance of package
- Copper and bronze double wall heat exchanger construction
- Clean in place heat exchanger
- main trap pre-piped and optional steam supply drip trap provided loose for field mounting
- Dual mixing valves provide ±4⁰F temperature control under variable load
- No control valve required for steam pressures under 15 PSIG
- Modbus connections with electronic control is optional
- Integral circulator
- ASME construction

Additional Information
Cobrex InstantaneousPVI Quickdraw Semi-Instantaneous QD and Quickdraw QS Storage Type Water Heaters
Features / Highlights
- 25-year warranty tank, 1-year balance of package
- AquaPLEX® dual metal SS heat tank engineered for domestic hot water heating and copper heat exchanger.
- Pre-piped main trap and optional steam supply drip trap provided loose for field mounting
- Electronic, pneumatic, or self-contained steam control valves
- Double wall or single wall models
- Modbus connections optional
- Integral circulator on Semi
- Includes insulation and jacketing
- ASME construction
PVI Cobrex-Storage Water Heater
Features / Highlights
- 3-year warranty on heat exchanger, 1-year balance of package
- Copper and bronze double wall heat exchanger construction
- Clean in place heat exchanger
- Pre-piped main trap and optional steam supply drip trap provided loose for field mounting
- No control valve required for steam pressures under 15 PSIG
- Modbus connections with electronic control is optional
- Integral circulator
- Tank and heat exchanger shipped as separate pieces
- ASME construction
Helpful tips, delivered to your inbox every Monday.
Hydronic Boiler Source Indirect Water Heaters
Often a hot water heating plant has extra capacity built in to use the boiler water as the source for heating domestic water. This provides several advantages including less gas-fired equipment, fewer vent protrusions in the structure, and less maintenance.
If the boilers used as the heat source are condensing type, there is an advantage of increasing the boiler plant efficiency using some types of indirect water heaters.
RL Deppmann provides packaged indirect boiler source water heaters from Aerco, Bock, Cemline, and PVI.
See the Dual Fuel/Alternate section of the website for combination water and gas models.
Additional Information
Looking for technical design information on indirect boiler water heaters?
Which Hydronic Boiler Indirect Water Heater Type Do I Need?
Answer a Few Quick Questions
Capacity Ranges for Hydronic Boiler Source Indirect Water Heaters – Semi & Storage Type
| Type of Water Heater | Brand and Model | Flow Rate or Recovery 40°F-140°F w/ 180°F | Packaged Temp Controls? | Storage Gallons |
|---|---|---|---|---|
| Brazed Plate Double or Single Wall | PVI EZ Plate Storage | 293 to 7,200 GPH | Yes | 150 - 900 |
| Brazed Plate Double or Single Wall | Cemline SPH | 150 - 3,000 GPH | Yes | 60 - 680 |
| Brazed Plate Double or Single Wall | Cemline CCH | 150 - 3,000 GPH | No | 120 - 500 |
| U-Tube Double or Single Wall | Cemline | SSH | Yes | 30 - 60 |
| U-Tube Double or Single Wall | Cemline | SWH | Yes | 100 - 6,080 |
| U-Tube Double Wall | PVI Quickdraw QWD | 140 - 3,200 GPH | Yes | 150 - 1,000 |
| U-Tube Single Wall | PVI Quickdraw QW | 140 - 3,200 GPH | Yes | 150 - 1,000 |
| Helical non-code coil | Bock Sidekick | 88 - 224 GPH | No | 30 - 110 |
| Water Heater Double Wall | Brand and Model | Flow Rate or Recovery 40°F-140°F Plate Style and 180°F U-Tube Style | Storage Gallons |
|---|---|---|---|
| Brazed Plate | PVI EZ Plate | 10 - 120 GPH | none |
| Brazed Plate | Aerco SPDW-EV | 10 - 90 GPH | none |
| Brazed Plate | Cemline BPH | 10 - 70 GPH | none |
| Gasketed Plate | Cemline PFH | 10 - 100 GPH | none |
| Gasketed Plate | Aerco SPDW | 10 - 90 GPH | none |
| U-Tube | Cemline SEH | 4 - 106 GPH | 5 - 23 |
| Water Heater Single Wall | Brand and Model | Flow Rate or Recovery 40°F-140°F Plate Style and 180°F U-Tube Style | Storage Gallons |
|---|---|---|---|
| Gasketed Plate | Cemline PFH | 10 - 100 GPH | none |
| Gasketed Plate | Aerco SP | 10 - 90 GPH | none |
| Brazed Plate | Cemline BPH | 10 - 70 GPH | none |
| U-Tube | Cemline SEH | 4 - 106 GPH | 5 - 23 |
Aerco Tankless SPDW Double and SP Single-Wall SmartPlate Hydronic Source Indirect Water Heater
Features / Highlights
- Great for condensing boiler applications (as low as 5⁰F approach)
- Replaceable Gasketed Plate Style
- All Stainless, Copper or Copper Alloy Wetted Surfaces
- Single-point electrical connection
- 2-way or 3-way hydronic control valves
- PID temperature controls for ±4⁰F accuracy
- Available for high-pressure applications
- Modbus connections available as an option
- ASME construction
Aerco Tankless SPDW-EV Double- Wall SmartPlate Hydronic Source Indirect Water Heater
Features / Highlights
- Great for condensing boiler applications (as low as 5⁰F approach)
- Fixed Brazed Plate Style
- All Stainless, Copper or Copper Alloy Wetted Surfaces
- Single-point electrical connection
- 2-way or 3-way hydronic control valves
- PID temperature controls for ±4⁰F accuracy
- Available for high-pressure applications
- Modbus connections available as an option
- ASME construction

Additional Information
Learn more about Aerco SPDW-EV double wall smart plateCemline PFH Removable Plate and BPH Brazed Plate Tankless Single or Double-Wall Plate Type Hydronic Source Indirect Water Heater
Features / Highlights
- Great for condensing boiler applications (as low as 5⁰F approach)
- Removable Plate style Single or Double-Wall
- Optional redundant heat exchanger for standby
- Heat exchanger maintenance connections
- (2) strainers and pressure and temperature gauges pre-piped
- Heater circulating pump included
- Boiler 2-way or 3-way control valve included with 1000:1 turndown
- Cem-Trol II PID controller
- Modbus connections standard
- ASME construction

Additional Information
Learn more about Cemline PFH Removable Plate and BPH Brazed PlateCemline Instantaneous SEH-D Double Wall and SEH-S Single-Wall Water Heater
Features / Highlights
- 5-year warranty on pressure vessel, 1-year balance of package
- 316L SS tank, copper tubes, copper lined tube sheet, copper bundle wrapper for SSH only
- Pre-piped temperature and pressure gauges
- 2-way or 3-way electronic or pneumatic, boiler water control valves pre-piped
- Double-wall or single wall models
- Modbus connections standard with Cem-trol II controller with alarm bell
- Integral circulator
- Includes insulation and jacketing
- ASME construction
Cemline SPH Storage Single or Double-Wall Hydronic Source Indirect Water Heater

Additional Information
Learn more about Cemline SPH storage water heatersCemline CCH Storage Single or Double-Wall Hydronic Source Indirect Water Heater
Features / Highlights
- Stonesteel cement or 316L SS tank construction.
- Great for condensing boiler applications (as low as 5⁰F approach)
- Fixed Brazed Plate Single or Double-Wall Style
- Heat exchanger maintenance connections
- Strainer and gauges included
- Tank circulating pump included
- Boiler 2-way or 3-way control valve included
- Cem-Trol II PID controller
- Modbus connections standard
- ASME construction

Additional Information
Learn more about Cemline CCH storage water heatersCemline SSH Semi-Instantaneous and SWH Storage Type Water Heaters
Features / Highlights
- 5-year warranty on pressure vessel, 1-year balance of package
- 316L SS tank, copper tubes, copper-lined tube sheet, copper bundle wrapper.
- Pre-piped main steam trap and steam supply drip trap and strainers
- Electronic, pneumatic, or self-contained steam control valves
- Double-wall or single-wall models
- Modbus connections standard with Cem-trol II controller
- Integral circulator
- Includes insulation and jacketing
- ASME construction
PVI EZ Plate Tankless Double-Wall Hydronic Source Indirect Water Heater
Features / Highlights
- Great for condensing boiler applications (as low as 20⁰F difference between boiler supply and HW set point)
- Fixed Brazed Plate Style with HW recirc minimum only 4 GPM
- All Stainless, Copper, Brass, or Bronze Wetted Surfaces
- Single-point electrical connection
- Optional 2-way hydronic control valves with strainer
- PID temperature controls
- Modbus connections available as an option
- ASME construction
PVI EZ Plate Semi/Storage Double- Wall Hydronic Source Indirect Water Heater
Features / Highlights
- 25-year warranty tank, 1-year balance of package
- AquaPLEX® dual metal SS heat tank engineered for domestic hot water heating and copper heat exchanger
- Great for condensing boiler applications (as low as 10⁰F difference between boiler supply and HW set point)
- 100% redundant heat exchanger models available for standby
- Fixed Brazed Plate Style with HW recirc minimum only 4 GPM
- No boiler water control valve required (2-way boiler water valve is optional)
- All Stainless, Copper, Brass, or Bronze Wetted Surfaces
- Circulator and tank piping included
- Clean in-place connections for heat exchanger
- PID temperature controls
- Modbus connections available as an option
- ASME construction
PVI Quickdraw Semi-Instantaneous/Storage Single-Wall (QW) and Double-Wall (QWD) Source Indirect Water Heater
Features / Highlights
- 25-year warranty tank, 1-year balance of package
- AquaPLEX® dual metal SS heat tank engineered for domestic hot water heating and copper heat exchanger
- Great for non-condensing boiler applications where storage is required
- On/Off boiler 3-way control valve
- Double-wall or single-wall U-tube heat exchanger
- Temptrac PID controller
- Modbus connections optional
- Auto-reset high limit
- Includes insulation and jacketing
- ASME construction
Contact the R.L. Deppmann Company
Alternate and Dual Fuel Water Heaters
Traditionally dual fuel is oil and gas. We offer gas/propane and oil vertical tank type water heaters. Sometimes dual fuel requires a different unfired solution. R. L. Deppmann provides brands that offer a mixture of types of heat sources in storage type water heaters.
Dual Source Water Heater Options
| Brand | Model | Dual Source Options |
|---|---|---|
| Bock | Dual Fuel (DF) | n. gas propane & n. gas oil & propane oil |
| Cemline | CTB | any combination of: unfired electric steam hydronic water wastewater |
| Cemline | SW | solar combined with any: electric steam hydronic condensing or non-condensing |
| PVI | Turbopower | n. gas oil & propane oil |
| PVI | FlexFuel | any combination of: n. gas electric steam hydronic water wastewater solar |
Bock Dual Fuel (DF) Water Heater
Features / Highlights
- Glass-lined steel tank with 4 to 11 anodes
- 3-year warranty on tank and heat exchanger
- Combination of: oil/natural gas or oil/propane or natural gas/propane
- Non-condensing
- 160-to-242-gallon storage
- 400 to 1,500 MBH recovery
- ASME construction

Additional Information
Want More Information about Bock Dueal Fuel water heaters?PVI TurboPower Water Heater
Features / Highlights
- AquaPLEX® dual metal SS heat exchanger and tank engineered for domestic hot water heating
- 25-year warranty on tank, 10 years on heat exchanger
- First-year service policy included with authorized startup
- Combination of: oil/natural gas or oil/propane
- 83% thermal efficiency non-condensing
- 150-to-1,500-gallon storage
- 399 to 2,000 MBH recovery
- CSD-1 controls optional
- Modbus connections available
- ASME construction

Additional Information
Want More Information about PVI TurboPower water heaters?PVI Flex Fuel Water Heater
Features / Highlights
- AquaPLEX® dual metal SS heat exchanger and tank engineered for domestic hot water heating
- 25-year warranty on tank
- Combination of any two sources: gas, electric, steam, hydronic water, wastewater, solar
- Engineered to order
- 215-to-4500-gallon storage
- Modbus connections: setpoint control, temperature, and alarms. BACnet gateway available.
- ASME construction

Additional Information
Want More Information about PVI FLex Fuel water heaters?Cemline CTB and SW Duel Unfired Water Heater
Features / Highlights
- Stonesteel cement lined steel tank (316L SS available)
- 5-year warranty on lining
- Combination of any two sources: Electric, steam, hydronic water, wastewater, solar
- Engineered to order
- 120-to-1000-gallon storage (Others available)
- Wide range or recovery capacities available
- Complete package with circulating pump, controls, gauges, and insulation
- 2- or 3-way control valves
- Modbus connections: setpoint control, temperature, and alarms. BACnet gateway available
- ASME construction

Additional Information
Want More Information about Cemline CTP and SW Duel unfired water heaters?Helpful tips, delivered to your inbox every Monday.
Tanks and Trim
Domestic Water Storage Tanks
Additional storage may be added to any domestic hot water system when dump loads challenge the water heater capacity. Hot water tanks are either steel with a lining or stainless steel. All tanks meet the NSF-61 low lead requirements.
| Manufacturer | Storage (Gallons) | Tank Material or Lining | Warranty1 | Comments |
|---|---|---|---|---|
| Bock | 119-1,128 | Glass lined | 5 | Jacket and insulated |
| Cemline | 120-3,920 | STONESTEEL® Cement | 5 | Coils available |
| Niles | 175-1,689 | Ultonium® glass lined | 15 (10/5) | Stainless steel tanks available |
| PVI | 125-3,000 | AquaPLEX® Duplex SS | 25 (15/10) | No anodes required. 200⁰F |
| Wessels | 120 – 1000 | WesGlas® glass lined | 5 | Coils available |
Tanks are available in horizontal configuration at larger capacities from some manufacturers.
Some tanks are available for immediate shipment from the manufacturer’s inventory, Call if you have a need for fast replacement of your tank.
| Manufacturer | Storage (Gallons) | Tank Material or Lining | Warranty1 | Comments |
|---|---|---|---|---|
| Bock | 119-1,128 | Glass lined | 5 | Jacket and insulated |
| Cemline | 120-3,920 | STONESTEEL® Cement | 5 | Coils available |
| Niles | 175-1,689 | Ultonium® glass lined | 15 (10/5) | Stainless steel tanks available |
| PVI | 125-3,000 | AquaPLEX® Duplex SS | 25 (15/10) | No anodes required. 200⁰F |
| Wessels | 120 – 1000 | WesGlas® glass lined | 5 | Coils available |
| PVI | 150-4,500 | 15 year non-prorated, 10 year additional prorated | ||
| Cemline | 100-8,600 | STONESTEEL® Cement | 5 year non-prorated | Coils available |
| Bock | 119-6141 | Glass lined | ASMEHorizntal insulated | |
| Bock | 30-119 | Glass lined | Non-code Vertical insulated and jackets | |
| Niles | 210-6138 | Ultonium® glass loned | 10/5 | |
| NTI | 40-119 | Stainless steel | Non-code with boiler coil | |
| Wessels | 120 – 1000 | WesGlas® glass lined | Ins jacket | |
| Wessels | 200-1500 | WesGlas® glass lined | Bare Tank |

Additional Information
Visit Bock Water Heater Tanks
Additional Information
Visit Cemline Tanks
Additional Information
Visit PVI storage tanksWhether you have a question about the product or want information on product availability and pricing, we've got you covered.






















