Why RL Deppmann for Your Water Heater?

Whatever your needs are for water heaters, R L Deppmann offers a high level of technical service, a broad product line of reputable products, and engineering expertise.

  • Extensive offering of high-quality products from trusted manufacturers to fit your needs
  • Engineering, technical, and application knowledge to save you time and lower your risk
  • Installation tips and troubleshooting assistance from our field techs and inside service team
  • The expertise to help you choose the correct product for your project

Which Gas Fired Water Heater Type Do I Need?

Answer a Few Questions to Find Out


Gas and Propane-Fired Tank Type Condensing Storage Water Heaters

Tank type water heaters have a high recovery burner coupled with some storage to handle larger peak demands or dump loads.  R. L. Deppmann offers PVI and Bock brands. They look like your residential water heater but the similarities in our brands end there.

Which one should I choose?

BrandWarrantyEfficiency1st costLifetime Cost
PVI15-25 years97%$$$$$$
Bock5 years99%$$$$$$$
Many competitors1-3 years95%$ to $$$$$$$$$

Two fine quality brands of products which serve different needs.  The choices are lower first cost vs. lower lifetime costs.

Capacity Ranges for Gas-Fired Tank Type Water Heaters

BrandModelCapacity MBHStorage GallonsEfficiencyWidth
PVITurbopower 96500-1600300-150097.5%64"-81"
PVIConquest 130399-100013097%34"
PVIConquest 100199-30010097%28"
BockOPT125-50099-12599%28"-32"

PVI by WATTS Gas-Fired Tank Type Condensing Water Heaters

Features / Highlights

  • AquaPLEX® dual metal SS heat exchanger and tank engineered for domestic hot water heating
  • 15 or 25 year pro-rated warranty depending on the model
  • Single Pass heat exchangers increase efficiency
  • TurboPower has replaceable burner assembly
  • No anodes to replace
  • Internally-controlled circulator pump reduces scaling
  • ASME tank is standard
  • Designed with controls for automatic disinfection
  • Choice of venting (SS, PVC, CPVC, Poly)
  • Vent sensor safety system matches vent material
  • Low life-cycle cost
  • Turbopower96 has replacement heat exchanger and burner assembly

Bock OptiTHERM Gas-Fired Tank Type Condensing Water Heaters

Features / Highlights

  • Glass-fused-to-steel water tank and heat exchanger
  • 5-year limited warranty better than most competitors
  • No anodes to replace
  • Dual TurboFlue® heat exchanger
  • ASME tank is available on most models
  • Choice of venting (SS, PVC, CPVC, Poly)

Gas-Fired Tank Type Non-Condensing Storage Water Heaters

Today’s commercial and institutional buildings use high-efficiency condensing boilers. There are some replacement applications for older technology.

BrandModelCapacity MBHStorage Gallons
PVITurbopower199-2000150-1500
PVIMaxim270-800250
PVIMaxim199-520125
BockEnergy Saver76-150030-119
BockEZ-Fit99-19975-100

Image

Additional Information

Learn more about PVI Turbopower

Image

Additional Information

Learn more about Bock EZ Fit

Gas and Propane Fired Tankless Condensing Water Heaters

Tankless water heaters combine the high efficiency of condensing water heaters with the immediate availability of hot water. The storage inside of a tankless heater is very minimal and used to protect people from temperature fluctuations due to immediate load changes. Tankless design efficiency is superior to instantaneous designs, particularly at low and recirculation loads.

See the Dual Fuel section of the website for combination electric and gas models

Capacity Ranges for Tankless Water Heaters

BrandModelMBH InputRecovery GPH/GPM
40°F - 140°F
Volume GallonsEfficiency
Aerco InnovationINN 135013501572 / 26.219.996%
Aerco InnovationINN 106010601224 / 20.42295%
Aerco InnovationINN 800N800924 / 15.425.394%
Aerco InnovationINN 600N625696 / 11.625.393%
PVI Brigade20L 25 RGC1992332597.5%

Aerco Innovation Tankless Condensing Water Heaters

Features / Highlights

  • AERguard stainless steel helical firetube heat exchanger assembly is thermal shockproof and scale resistant
  • Warranty: 10 year on pressure vessel and heat exchanger. 2 year on the controller, 1 year balance of trim
  • Small footprint and fits through 36” door
  • Available Edge controller with diagnostics and mobile application
  • Modulating up to 27:1 turndown with ±4⁰F accuracy
  • Set points up to 190⁰F
  • Sequence up to 16 water heaters in parallel
  • Up to 99% efficiency
  • Low life-cycle cost
  • ASME Construction

PVI Brigade Tankless Condensing Water Heaters

Features / Highlight

  • AquaPLEX® duplex SS heat exchanger and tank engineered for domestic hot water heating
  • Full 6 year warranty
  • Very small footprint -16” x 23” floor space
  • Set points up to 185⁰F
  • Modulating up to 7:1 turndown
  • Sequence up to 6 water heaters in parallel
  • Up to 99% efficiency
PVI Brigade Right Tankless Water Heater

Additional Information

More information on PVI Brigade

Gas and Propane Fired Condensing Volume Water Heaters

Volume water heaters are designed with a separate heater and tank. The water heater has little volume and requires a specific range of flow rates. To accomplish this, a Bell & Gossett all bronze or SS pump is used between the tank and the heater.

R. L. Deppmann offers NTI, Thermal Solutions, Aerco, and PVI brands.

Image

Capacity Ranges for Gas Fired Volume Water Heaters

BrandModelCapacity
MBH
Thermal SolutionsAMPW400-3,920
NTILx-WH199-300

NTI Lx-WH Gas Fired Condensing Commercial Volume Water Heaters

Features/Highlights

  • Touch screen controls
  • Modulating 8:1 turndown
  • Stainless steel heat exchanger
  • Up to 96% efficiency

Volume water heaters require a separate tank and circulating pump. The tank are shown in the tank section of this webpage. The following is the suggested pump to use assuming no more than 5 feet of pipe valve and fitting losses.

NTI Lx-WH
Model
MBH1Recovery GPH1Min Pump GPMSuggest Pipe Size2Constant Speed Circulator3ecm Smart Pump3
200199229161-1/2"PL-36B-1/6HPXL-N-36-45
300275317242"PL-55B-2/5HPXL-N-36-45
400399460322"60-Be606-1/2HPXL-N-55-45
500500576403"60-Be6134-3/4HPXL-N-65-130
600600691483"60-Be6133-3/4HPXL-N-65-130
700700806563"60-Be609-3/4HPXL-N-65-130
800800922644"60-Be614-1HPXL-N-65-130
(1) Based on 40°F to 140°F with minimum vent distance.
(2) Based on velocity less than 4 FPS
(3) Based on Bell & Gossett with 5 ft. pipe and valve PD allowance
(4) BTO Bronze pump with equivalent impeller

Thermal Solutions AMPW Gas Fired Condensing Commercial Volume Water Heaters

Features/Highlights

  • Small footprint and stackable
  • Dual fuel switchable – Nat. gas and propane
  • Touch control with self-guided diagnostics.
  • Modulating 5:1 turndown
  • Sequence up to 8 water heaters in parallel
  • 316L Stainless steel heat exchanger
  • Up to 98% efficiency
Thermal Soluti0ns AMPW ModelMBH1Recovery GPH1Min Pump GPMSuggest Pipe Size2Constant Speed Circulator3ecm Smart Pump3
AMPW-10009801176994"60-Be611-3/4HPXL-N-40-200
AMPW-125012251485994"60-Be611-3/4HPXL-N-40-200
AMPW-1500147017821104"60-Be627-1-1/2HPXL-N-40-200
AMPW-2000196023761384"60-Be627-1-1/2HPXL-N-40-200
AMPW-2500245029702146"92SV-1-3HPXL-N-40-275
AMPW-3000294035642146"92SV-1-3HPXL-N-40-275
AMPW-3500343041582146"92SV-1-3HPXL-N-40-275
AMPW-4000392047522146"92SV-1-3HPXL-N-40-275
(1) Based on 40°F to 140°F with minimum vent distance.
(2) Based on velocity less than 4 FPS
(3) Based on Bell & Gossett with 5 ft. pipe and valve PD allowance
(4) BTO Bronze pump with equivalent impeller
(5) Flow and pump selection based on 5-12 grains gpg hardness
Contact RLD for other conditions.
Volume water heaters require a separate tank and circulating pump. The tank are shown in the tank section of this webpage. The following is the suggested pump to use assuming no more than 5 feet of pipe valve and fitting losses
Check out our Monday Morning Minutes

Helpful tips, delivered to your inbox every Monday.


Electric Water Heaters

RL Deppmann joins the electrification effort with a wide variety of electric water heaters to fit multiple codes, service requirements, and budgets. In general, electric water heaters are 98% efficiency or higher. Most models have many options available to fit your project requirements.

See the Dual Fuel section of the website for combination electric and gas models.

Capacity Ranges for Electric Water Heaters

Brand and ModelGPH Recovery
40°F to 100°F
kW RangeStorage
Gallons
Tank
Type
PVI Durawatt Spec70-59018-144119-4500Horizontal ASME
PVI Durawatt Std70-59018-144119-750Vertical ASME
Bock Electritherm CE54-21713.5-5450-119Vertical Non-code
Bock LVE Large KW Electric49-147612-360150-2500Vertical ASME
Cemline H-EHB Electric49-98412-240120-6080Horizontal ASME
Cemline V-EHB Electric49-98412-24040-3920Vertical ASME
Bock Commercial Electric25-2236-5450-119Vertical ASME
Bock LCE nDurance6-241.5-66-20Shel Non-code
NTI Compact Electric6.81.442.7-7Wall Mtd. Non-code

PVI Durawatt® Water Heater

Features/Highlights

  • AquaPLEX® duplex SS heat exchanger and tank engineered for domestic hot water heating
  • 25-year warranty on tank and elements
  • Incoloy or copper sheathed heating elements std w/non-ferrous waterside connections. Electro-polished Incoloy available
  • Elements individually mounted with flanged bronze connections
  • Modbus connections: setpoint control, temperature, and alarms. BACnet gateway available
  • ASME construction
PVI Durawatt electric water heater

Additional Information

Want more information on Durawatt?

Cemline EHB Water Heater

  • Stonesteel cement lined steel tank
  • 5-year warranty on the lining
  • Incoloy or copper sheathed heating elements
  • Elements individually mounted with flanged non-ferrous connections
  • Modbus connections: setpoint control, temperature, and alarms. BACnet gateway is available
  • ASME construction
Cemline EHB electric Water Heater

Additional Information

Want more info on Cemline VEHB?

Bock ElectriTHERM, Commercial Electric CF and Large kW LVE Water Heater

 Features/Highlights

  • Glass-lined steel tank
  • 3-year warranty on ASME product
  • Incoloy sheathed heating elements
  • Screw-in elements on CF and ElectriTHERM
  • BMS connections available
  • ElectriTherm is non-code and CF and LVE are ASME construction

Bock nDurance LCE Point of Use Water

 Features/Highlights

  • Glass fused steel tank
  • 5-year warranty
  • copper sheathed single or dual heating element
  • Leak sensor and shutoff valve optional
  • Non-code 150 PSIG construction
Image

Additional Information

Want more on Brock nDurance?

We're Here to Help!

Whether you have a question about the product or want information on product availability and pricing, we've got you covered.


Indirect Steam Water Heaters

Which Indirect Steam Water Heater Type Do I Need?

Answer a Few Questions to Find Out

Capacity Ranges for Indirect Steam Water Heaters

Water Heater
Double Wall
Brand and ModelFlow Rate or Recovery
40°F-140°F
Storage
Gallons
InstantaneousAerco SWDW0-150 GPM**None
InstantaneousCemline SEH-D0-120 GPMNone
InstantaneousPVI Cobrex-CCX20-120 GPHNone
Semi-InstantaneousCemline SSH-D0-200 GPM30-60
Semi-InstantaneousPVI Cobrex Semi-ISD8-59 GPM10-80
Semi-InstantaneousPVI Quickdraw Semi QD-ISD0-74 GPM50-100
StorageCemline SWH-D148-12,220 GPH100-6,080
StoragePVI Cobrex Storage QSD0-8,425 GPH250-1,000
StoragePVI Quickdraw Storage QS-ISD200-3,200 GPH150-900
**180 GPM Intermittent

 

Water Heater
Single Wall
Brand and ModelFlow Rate or Recovery
40°F-140°F
Storage
Gallons
InstantaneousAerco B+II0-125 GPM***None
InstantaneousCemline SEH-S0-120 GPMNone
Semi-InstantaneousCemline SSH-S0-200 GPM30-60
StoragePVI Quickdraw Storage QS-IS200-3,200 GPH150-900
StorageCemline SWH-S148-12,220 GPH100-6,080
Semi-InstantaneousPVI Quickdraw Semi QD-IS0-74 GPM50-100
***250 GPM Intermittent

Aerco Instantaneous SWDW Double Wall & B+II Single Wall Water Heater

Features/Highlights

  • On B+II, 20-year warranty on pressure vessel and demand anticipator, 10-year complete heat exchanger, 1-year balance of package
  • All Stainless, TFE, Copper or Copper Alloy Wetted Surfaces
  • Main steam trap and optional steam supply drip trap and strainers shipped loose
  • Aerco monitoring system for ±4⁰F temperature control under normal load changes
  • UL Listed double wall or single wall models
  • Modbus connections available as option
  • ASME construction

Cemline Instantaneous SEH-D Double Wall and SEH-S Single Wall Water Heater

Features/Highlights

  • 5-year warranty on pressure vessel, 1-year balance of package
  • 316L SS shell, copper tubes, copper-lined tube sheet, copper bundle wrapper
  • Pre-piped main steam trap and steam supply drip trap and strainers
  • Electronic, pneumatic, or self-contained steam control valves
  • Double-wall or single-wall models
  • Modbus connections standard with Cem-trol II controller
  • Integral circulator
  • Includes insulation and jacketing
  • ASME construction

Cemline SSH Semi-Instantaneous and SWH Storage Type Water Heaters

Features / Highlights

  • 5-year warranty on pressure vessel, 1-year balance of package
  • 316L SS tank, copper tubes, copper lined tube sheet, copper bundle wrapper for SSH only
  • Great for non-condensing applications with boiler water 160⁰F or more
  • Electronic or pneumatic control valve pre-piped
  • Double wall or single wall models
  • Modbus connections standard with Cem-trol II controller
  • Integral circulator
  • Includes insulation and jacketing
  • ASME construction

PVI Cobrex CCX Instantaneous Double Wall Water Heater

Features / Highlights

  • 3-year warranty on heat exchanger, 1-year balance of package
  • Copper and bronze double wall heat exchanger construction
  • Clean in place heat exchanger
  • main trap pre-piped and optional steam supply drip trap provided loose for field mounting
  • Dual mixing valves provide ±4⁰F temperature control under variable load
  • No control valve required for steam pressures under 15 PSIG
  • Modbus connections with electronic control is optional
  • Integral circulator
  • ASME construction
PVI Cobrex Instantaneous Indirect Steam Water Heater

Additional Information

Cobrex Instantaneous

PVI Quickdraw Semi-Instantaneous QD and Quickdraw QS Storage Type Water Heaters

Features / Highlights

  • 25-year warranty tank, 1-year balance of package
  • AquaPLEX® dual metal SS heat tank engineered for domestic hot water heating and copper heat exchanger.
  • Pre-piped main trap and optional steam supply drip trap provided loose for field mounting
  • Electronic, pneumatic, or self-contained steam control valves
  • Double wall or single wall models
  • Modbus connections optional
  • Integral circulator on Semi
  • Includes insulation and jacketing
  • ASME construction

PVI Cobrex-Storage Water Heater

Features / Highlights

  • 3-year warranty on heat exchanger, 1-year balance of package
  • Copper and bronze double wall heat exchanger construction
  • Clean in place heat exchanger
  • Pre-piped main trap and optional steam supply drip trap provided loose for field mounting
  • No control valve required for steam pressures under 15 PSIG
  • Modbus connections with electronic control is optional
  • Integral circulator
  • Tank and heat exchanger shipped as separate pieces
  • ASME construction
Check out our Monday Morning Minutes

Helpful tips, delivered to your inbox every Monday.


Hydronic Boiler Source Indirect Water Heaters

Often a hot water heating plant has extra capacity built in to use the boiler water as the source for heating domestic water. This provides several advantages including less gas-fired equipment, fewer vent protrusions in the structure, and less maintenance.

If the boilers used as the heat source are condensing type, there is an advantage of increasing the boiler plant efficiency using some types of indirect water heaters.

RL Deppmann provides packaged indirect boiler source water heaters from Aerco, Bock, Cemline, and PVI.

See the Dual Fuel/Alternate section of the website for combination water and gas models.

Which Hydronic Boiler Indirect Water Heater Type Do I Need?

Answer a Few Quick Questions

Capacity Ranges for Hydronic Boiler Source Indirect Water Heaters – Semi & Storage Type

Type of Water HeaterBrand and ModelFlow Rate or Recovery
40°F-140°F w/ 180°F
Packaged Temp Controls?Storage Gallons
Brazed Plate Double or Single WallPVI EZ Plate Storage293 to 7,200 GPHYes150 - 900
Brazed Plate Double or Single WallCemline SPH150 - 3,000 GPHYes60 - 680
Brazed Plate Double or Single WallCemline CCH150 - 3,000 GPHNo120 - 500
U-Tube Double or Single WallCemlineSSHYes30 - 60
U-Tube Double or Single WallCemlineSWHYes100 - 6,080
U-Tube Double WallPVI Quickdraw QWD140 - 3,200 GPHYes150 - 1,000
U-Tube Single WallPVI Quickdraw QW140 - 3,200 GPHYes150 - 1,000
Helical non-code coilBock Sidekick88 - 224 GPHNo30 - 110

Water Heater
Double Wall
Brand and ModelFlow Rate or Recovery
40°F-140°F Plate Style and 180°F U-Tube Style
Storage Gallons
Brazed PlatePVI EZ Plate10 - 120 GPHnone
Brazed PlateAerco SPDW-EV10 - 90 GPHnone
Brazed PlateCemline BPH10 - 70 GPHnone
Gasketed PlateCemline PFH10 - 100 GPHnone
Gasketed PlateAerco SPDW10 - 90 GPHnone
U-TubeCemline SEH4 - 106 GPH5 - 23

 

Water Heater
Single Wall
Brand and ModelFlow Rate or Recovery
40°F-140°F Plate Style and 180°F U-Tube Style
Storage Gallons
Gasketed PlateCemline PFH10 - 100 GPHnone
Gasketed PlateAerco SP10 - 90 GPHnone
Brazed PlateCemline BPH10 - 70 GPHnone
U-TubeCemline SEH4 - 106 GPH5 - 23

Aerco Tankless SPDW Double and SP Single-Wall SmartPlate Hydronic Source Indirect Water Heater

Features / Highlights

  • Great for condensing boiler applications (as low as 5⁰F approach)
  • Replaceable Gasketed Plate Style
  • All Stainless, Copper or Copper Alloy Wetted Surfaces
  • Single-point electrical connection
  • 2-way or 3-way hydronic control valves
  • PID temperature controls for ±4⁰F accuracy
  • Available for high-pressure applications
  • Modbus connections available as an option
  • ASME construction

Aerco Tankless SPDW-EV Double- Wall SmartPlate Hydronic Source Indirect Water Heater

Features / Highlights

  • Great for condensing boiler applications (as low as 5⁰F approach)
  • Fixed Brazed Plate Style
  • All Stainless, Copper or Copper Alloy Wetted Surfaces
  • Single-point electrical connection
  • 2-way or 3-way hydronic control valves
  • PID temperature controls for ±4⁰F accuracy
  • Available for high-pressure applications
  • Modbus connections available as an option
  • ASME construction

Cemline PFH Removable Plate and BPH Brazed Plate Tankless Single or Double-Wall Plate Type Hydronic Source Indirect Water Heater

Features / Highlights

  • Great for condensing boiler applications (as low as 5⁰F approach)
  • Removable Plate style Single or Double-Wall
  • Optional redundant heat exchanger for standby
  • Heat exchanger maintenance connections
  • (2) strainers and pressure and temperature gauges pre-piped
  • Heater circulating pump included
  • Boiler 2-way or 3-way control valve included with 1000:1 turndown
  • Cem-Trol II PID controller
  • Modbus connections standard
  • ASME construction

Cemline Instantaneous SEH-D Double Wall and SEH-S Single-Wall Water Heater

Features / Highlights

  • 5-year warranty on pressure vessel, 1-year balance of package
  • 316L SS tank, copper tubes, copper lined tube sheet, copper bundle wrapper for SSH only
  • Pre-piped temperature and pressure gauges
  • 2-way or 3-way electronic or pneumatic, boiler water control valves pre-piped
  • Double-wall or single wall models
  • Modbus connections standard with Cem-trol II controller with alarm bell
  • Integral circulator
  • Includes insulation and jacketing
  • ASME construction
Cemline DSC 1688 Path Indirect Boiler Water Heater

Additional Information

Learn more about Cemline SEH

Cemline SPH Storage Single or Double-Wall Hydronic Source Indirect Water Heater

Features / Highlights

  • Stonesteel cement or 316L SS tank construction.
  • Great for condensing boiler applications (as low as 5⁰F approach)
  • Fixed Brazed Plate Single or Double-Wall Style
  • Gauges included
  • Tank circulating pump included
  • No controls included - All controls by others
  • ASME construction

Cemline CCH Storage Single or Double-Wall Hydronic Source Indirect Water Heater

Features / Highlights

  • Stonesteel cement or 316L SS tank construction.
  • Great for condensing boiler applications (as low as 5⁰F approach)
  • Fixed Brazed Plate Single or Double-Wall Style
  • Heat exchanger maintenance connections
  • Strainer and gauges included
  • Tank circulating pump included
  • Boiler 2-way or 3-way control valve included
  • Cem-Trol II PID controller
  • Modbus connections standard
  • ASME construction

Cemline SSH Semi-Instantaneous and SWH Storage Type Water Heaters

Features / Highlights

  • 5-year warranty on pressure vessel, 1-year balance of package
  • 316L SS tank, copper tubes, copper-lined tube sheet, copper bundle wrapper.
  • Pre-piped main steam trap and steam supply drip trap and strainers
  • Electronic, pneumatic, or self-contained steam control valves
  • Double-wall or single-wall models
  • Modbus connections standard with Cem-trol II controller
  • Integral circulator
  • Includes insulation and jacketing
  • ASME construction

PVI EZ Plate Tankless Double-Wall Hydronic Source Indirect Water Heater

Features / Highlights

  • Great for condensing boiler applications (as low as 20⁰F difference between boiler supply and HW set point)
  • Fixed Brazed Plate Style with HW recirc minimum only 4 GPM
  • All Stainless, Copper, Brass, or Bronze Wetted Surfaces
  • Single-point electrical connection
  • Optional 2-way hydronic control valves with strainer
  • PID temperature controls
  • Modbus connections available as an option
  • ASME construction

PVI EZ Plate Semi/Storage Double- Wall Hydronic Source Indirect Water Heater

Features / Highlights

  • 25-year warranty tank, 1-year balance of package
  • AquaPLEX® dual metal SS heat tank engineered for domestic hot water heating and copper heat exchanger
  • Great for condensing boiler applications (as low as 10⁰F difference between boiler supply and HW set point)
  • 100% redundant heat exchanger models available for standby
  • Fixed Brazed Plate Style with HW recirc minimum only 4 GPM
  • No boiler water control valve required (2-way boiler water valve is optional)
  • All Stainless, Copper, Brass, or Bronze Wetted Surfaces
  • Circulator and tank piping included
  • Clean in-place connections for heat exchanger
  • PID temperature controls
  • Modbus connections available as an option
  • ASME construction

PVI Quickdraw Semi-Instantaneous/Storage Single-Wall (QW) and Double-Wall (QWD) Source Indirect Water Heater

Features / Highlights

  • 25-year warranty tank, 1-year balance of package
  • AquaPLEX® dual metal SS heat tank engineered for domestic hot water heating and copper heat exchanger
  • Great for non-condensing boiler applications where storage is required
  • On/Off boiler 3-way control valve
  • Double-wall or single-wall U-tube heat exchanger
  • Temptrac PID controller
  • Modbus connections optional
  • Auto-reset high limit
  • Includes insulation and jacketing
  • ASME construction

Bock Sidekick Storage Tank with Single Wall Coil

Features / Highlights

This is a non-code tank with a coil in it for indirect heating from a non-condensing boiler. It has no controls and is for residential and small commercial use.

  • Glass-lined tank and coil
  • 2 anodes included
  • No boiler water temp controls included
  • Tank and heater circulator optional
  • Non-code construction
Request More Information

Contact the R.L. Deppmann Company


Alternate and Dual Fuel Water Heaters

Traditionally dual fuel is oil and gas. We offer gas/propane and oil vertical tank type water heaters. Sometimes dual fuel requires a different unfired solution. R. L. Deppmann provides brands that offer a mixture of types of heat sources in storage type water heaters.

Dual Source Water Heater Options

BrandModelDual Source Options
BockDual Fuel (DF)n. gas
propane & n. gas
oil & propane
oil
CemlineCTBany combination of:
unfired electric
steam
hydronic water
wastewater
CemlineSWsolar combined with any:
electric
steam
hydronic condensing or non-condensing
PVITurbopowern. gas
oil & propane
oil
PVIFlexFuelany combination of:
n. gas
electric
steam
hydronic water
wastewater
solar

Bock Dual Fuel (DF) Water Heater

Features / Highlights

  • Glass-lined steel tank with 4 to 11 anodes
  • 3-year warranty on tank and heat exchanger
  • Combination of: oil/natural gas or oil/propane or natural gas/propane
  • Non-condensing
  • 160-to-242-gallon storage
  • 400 to 1,500 MBH recovery
  • ASME construction

PVI TurboPower Water Heater

Features / Highlights

  • AquaPLEX® dual metal SS heat exchanger and tank engineered for domestic hot water heating
  • 25-year warranty on tank, 10 years on heat exchanger
  • First-year service policy included with authorized startup
  • Combination of: oil/natural gas or oil/propane
  • 83% thermal efficiency non-condensing
  • 150-to-1,500-gallon storage
  • 399 to 2,000 MBH recovery
  • CSD-1 controls optional
  • Modbus connections available
  • ASME construction

PVI Flex Fuel Water Heater

Features / Highlights

  • AquaPLEX® dual metal SS heat exchanger and tank engineered for domestic hot water heating
  • 25-year warranty on tank
  • Combination of any two sources: gas, electric, steam, hydronic water, wastewater, solar
  • Engineered to order
  • 215-to-4500-gallon storage
  • Modbus connections: setpoint control, temperature, and alarms. BACnet gateway available.
  • ASME construction

Cemline CTB and SW Duel Unfired Water Heater

Features / Highlights

  • Stonesteel cement lined steel tank (316L SS available)
  • 5-year warranty on lining
  • Combination of any two sources: Electric, steam, hydronic water, wastewater, solar
  • Engineered to order
  • 120-to-1000-gallon storage (Others available)
  • Wide range or recovery capacities available
  • Complete package with circulating pump, controls, gauges, and insulation
  • 2- or 3-way control valves
  • Modbus connections: setpoint control, temperature, and alarms. BACnet gateway available
  • ASME construction
Check out our Monday Morning Minutes

Helpful tips, delivered to your inbox every Monday.


Tanks and Trim

Domestic Water Storage Tanks

Additional storage may be added to any domestic hot water system when dump loads challenge the water heater capacity.  Hot water tanks are either steel with a lining or stainless steel. All tanks meet the NSF-61 low lead requirements.

ManufacturerStorage (Gallons) Tank Material or LiningWarranty1Comments
Bock119-1,128Glass lined5Jacket and insulated
Cemline120-3,920STONESTEEL® Cement5Coils available
Niles175-1,689Ultonium® glass lined15 (10/5)Stainless steel tanks available
PVI125-3,000AquaPLEX® Duplex SS25 (15/10)No anodes required. 200⁰F
Wessels120 – 1000WesGlas® glass lined5Coils available
Notes: All tanks are ASME construction and stamped. (1) Total limited warranty period. (XX/XX) indicates period (non-prorated/prorated)

Tanks are available in horizontal configuration at larger capacities from some manufacturers.

Some tanks are available for immediate shipment from the manufacturer’s inventory, Call if you have a need for fast replacement of your tank.

ManufacturerStorage (Gallons) Tank Material or LiningWarranty1Comments
Bock119-1,128Glass lined5Jacket and insulated
Cemline120-3,920STONESTEEL® Cement5Coils available
Niles175-1,689Ultonium® glass lined15 (10/5)Stainless steel tanks available
PVI125-3,000AquaPLEX® Duplex SS25 (15/10)No anodes required. 200⁰F
Wessels120 – 1000WesGlas® glass lined5Coils available
PVI150-4,50015 year non-prorated, 10 year additional prorated
Cemline100-8,600STONESTEEL® Cement5 year non-proratedCoils available
Bock119-6141Glass linedASMEHorizntal insulated
Bock30-119Glass linedNon-code Vertical insulated and jackets
Niles210-6138Ultonium® glass loned10/5
NTI40-119Stainless steelNon-code with boiler coil
Wessels120 – 1000WesGlas® glass linedIns jacket
Wessels200-1500WesGlas® glass linedBare Tank
Notes: All tanks are ASME construction and stamped. (1) Total limited warranty period. (XX/XX) indicates period (non-prorated/prorated)
Image

Additional Information

Visit Bock Water Heater Tanks

Image

Additional Information

Visit Cemline Tanks

Image

Additional Information

Visit PVI storage tanks

We're Here to Help!

Whether you have a question about the product or want information on product availability and pricing, we've got you covered.